Principle and method of flow measurement: channelmaster H-ADCP is a fixed acoustic Doppler flow automatic meter for real-time monitoring of flow velocity and flow in rivers and open channels produced by Teledyne Rd instruments. H-ADCP can be used as an independent real-time monitoring system for flow velocity and flow rate by connecting with computer through cable. H-ADCP can also be integrated with other instruments and equipment to form a water quality and quantity telemetry station. At present, channelmaster H-ADCP has three frequencies: 1200 kHz, 600 kHz and 300 kHz, which are suitable for sections with different widths.
Channelmaster H-ADCP measures the flow rate by two horizontal ultrasonic probes and the water level by ultrasonic water level gauge, so as to complete the flow measurement and calculation.
H-ADCP can be used for flow measurement by index velocity method. The index velocity method is to establish the correlation between the measured velocity (index velocity) of H-ADCP and the average velocity of river or open channel section, that is, to calibrate the system with the measured data to measure the flow. The specific comparison and calibration method is to use H-ADCP to measure the flow velocity (index flow velocity) and other methods to calculate the real flow of the river. According to the water level and the known large cross section, the flow area of the cross section can be calculated. The average flow velocity of the cross section can be obtained by dividing the flow by the flow area of the cross section; At this time, the velocity (index velocity) measured by H-ADCP corresponds to the average velocity of the section. Under different discharge and water depth, multiple sets of index velocity and section average velocity are obtained. Through regression analysis (using the least square method), the correlation (regression equation) between section average velocity and H-ADCP measured velocity (index velocity) can be established.
The main advantages of channelmaster H-ADCP are as follows:
-Trdi broadband patent technology is adopted.
- High precision, high spatial and temporal resolution. The accurate velocity data can be obtained in a short sampling time step with a smaller cell.
- High quality test data can also be obtained for low velocity and unsteady flow which are difficult to test.
- Standard configuration: 1-128 optional units, 0.2-10m optional unit length, 1-300m profile range (depending on system frequency). More velocity data can be obtained, so that the distribution of water flow in the horizontal direction can be measured, which has great flexibility.
- The standard configuration of ultrasonic water level gauge and pressure water level gauge makes the water level measurement more accurate and reliable.
- Standard inclinometer. Inclinometer plays an important role in adjusting the H-ADCP mounting bracket and monitoring the tilt change of the mounting bracket, so as to ensure the quality of test data.
- The standard stainless steel mounting base makes the installation of H-ADCP very convenient.
- Using the latest acoustic Doppler technology. It has the advantages of easy installation, simple operation, not easily affected by biological attachment, moderate price and convenient maintenance.
- There are many kinds of interface for data communication, which is convenient for system integration.
The technical specifications of velocity profile measurement (broadband patent technology) of channelmaster H-ADCP are as follows:
System frequency |
300kHz |
600kHz |
1200kHz |
Number of units |
1~128 |
1~128 |
1~128 |
Blind area (m) |
1.0 |
0.5 |
0 |
Minimum unit length (m) |
1.0 |
0.5 |
0.25 |
Maximum unit length (m) |
8 |
4 |
4 |
Maximum profile range (m) |
300 |
90 |
20 |
Flow rate range (M / s) |
±twenty |
±twenty |
±twenty |
Velocity measurement accuracy |
0.5%±0.2cm/s |
0.5%±0.2 cm/s |
0.5%±0.2 cm/s |
Velocity resolution (M / s) |
0. 001 |
0. 001 |
0. 001 |
Water level measurement (m) |
19 |
19 |
19 |
Water level measurement error |
0.5%±0.5cm |
0.5%±0.5cm |
0.5%±0.5cm |
Flow measurement error |
<5% |
<5% |
<5% |
Communication protocol |
Modbus or Modbus / TCP |
Modbus or Modbus / TCP |
Modbus or Modbus / TCP |
The technical specifications of channelmaster H-ADCP standard configuration sensor are as follows:
Serial number |
Standard sensor |
Technical index |
one |
Transducer for velocity measurement |
Configuration: dual beam ± twenty ° Beam angle; Beam width: 1200khz / 600kHz: 1.5 °, 300kHz: 2.2 °。 |
two |
Ultrasonic water level gauge |
Range: 0.1-19m; Accuracy: ± 0.25%; Resolution: 0.1 mm. |
three |
Pressure type water level gauge |
Range: 0.1-10m; Accuracy: ± 0.5%; Resolution: 1.0 mm. |
four |
Temperature probe |
Range: - 4-40 ℃; Accuracy: ± 0.2℃; Resolution: 0.01 ℃. |
five |
Inclinometer |
Range: ± fifteen °; Accuracy: ± zero point five °; Resolution: 0.01 ° |
Other indicators:
- Communication: RS-232, RS-422, RS-485, SDI-12
- Memory: 4m
- Anti vibration: meet IEC 721-3-2 standard
- Shell: polyurethane casting shell, titanium alloy connector
- Base: stainless steel mounting base
- Power supply: voltage: 10-18vdc, maximum current: 1.5A,
- The power consumption depends on the flow rate measurement parameters
- Special tools for maintenance: all kinds of special tools for daily maintenance.
- With time setting function, monitoring frequency can be set according to needs
- It has the functions of basic parameter storage, power-off protection and automatic recovery
- It has two-way data and signal transmission function