022-29398436
Agriculture, forestry, animal husbandry and fishery, industrial and mining enterprises, municipal engineering,hydrology
and water conservancy, scientific research institutions, real estate and construction industry, etc
Analysis method: silver ion in water and chromogenic agent produce stable color, measure the absorbance value of sample before and after adding chromogenic agent at specific wavelength, calculate the concentration of silver ion, and automatically compensate the chromaticity of sample.
♦ host
The microcomputer control processing unit is adopted:
Storage and logical operation functions
♦ touch screen:
Record data and files, save values and results, and store history
♦ Network functions:
Communication with LAN, remote operation with 4G to view data
♦ 24V DC power supply and power supply failure:
Automatic saving of parameters, history and clock of 24V DC power supply and power failure ♦ data collector:
Data acquisition value of single chip
♦ Data output function:
Ethernet (standard), USB serial port interface, RS232, RS485 (Modbus Communication Protocol)
♦ Signal status:
Correct passive points, maintenance contacts, remote / local contacts, analysis start, analysis reset, analysis wait, analysis pause.
♦ Analog data output:
Maximum load 600 ohm, 4-20mA (current blocking) provides two outputs
♦ Alarm function:
Machine fault alarm and upper and lower limit alarm of data
♦ Environmental Science:
Clean the room with relative humidity of 2% to 95% (without condensation),
10 – 30 ° C +/- 4 ° C deviation (50 ° F – 86 ° F +/- 7.2 ° F (deviation)
♦ Shell:
Protection grade IP65 (according to din40050) Dimensions (600 W x 450 x 1500mm h)
Shipment of 40kg, machine shell grounding device
♦ piping:
Peristaltic pump, micro pump, diaphragm pump, injection pump, discharge, instrument air, discharge
♦ Cleaning correction:
Demineralization purified water / distilled water for calibration, cleaning, dilution, etc
Analyte Silver ion (Ag) concentration
Measurement range 0-20 mg / L (expandable)
basic operation
The analyzer has successfully passed a series of tests to facilitate installation and setting. During installation, just connect reagent, sample, waste liquid pipeline and power line, and set parameters to start. Automatic calibration, automatic cleaning, automatic testing, automatic data storage. Long time automatic control, low maintenance, low operation cost, automatic operation, low reagent consumption, short preparation time, simple maintenance, no special electrician training.