022-29398436
Agriculture, forestry, animal husbandry and fishery, industrial and mining enterprises, municipal engineering,hydrology
and water conservancy, scientific research institutions, real estate and construction industry, etc
The continuous flue gas emission monitoring system (in-situ) is composed of four basic parts: smoke monitoring subsystem, gaseous pollutant monitoring subsystem, flue gas parameter monitoring subsystem, system control and data acquisition and processing subsystem. It can monitor SO2, NOx, O2, dust, temperature, pressure, flow rate and other parameters in the gas. It can also expand the monitoring of HCl, HF, Co, CO2, humidity and other parameters for specific occasions. The measured gas directly enters into the high temperature gas analysis module (DOAS Technology) for analysis and measurement after dust removal by sampling probe. Without heat tracing tube and condenser, it has fast response time and effectively solves the technical problems such as low measurement results caused by water precipitation and absorption of SO2 by condensation method, especially in low concentration measurement occasions.
Ultraviolet absorption spectrum gas analysis technology and chemometrics algorithm are the advanced on-line analysis methods for NOx and other gases at present, with the detection limit of 1mg / m3;
By using holographic grating and diode array detection, a complete continuous absorption spectrum is obtained with high resolution, low detection limit, small temperature drift and fast response time;
There is no condensation process, which can avoid the low measurement caused by the absorption of SO2 by condensed water, and can truly reflect the working conditions;
No heat tracing tube, fast response time and low cost;
Compared with the extraction method, the analyzer has the advantages of accurate measurement, high reliability, low investment cost and fast response;
Compared with the in situ method, the analyzer has the advantages of on-line calibration, small fluctuation of measured value, high reliability and simple maintenance.
Application scenarios: coal fired power plant, garbage power plant, cement plant, glass plant, lime plant, ceramic plant, sintering plant, coke oven, desulfurization process, denitration process and other exhaust emission monitoring and process control.
SO2:0~50~1000ppm,O2 : 0~25%
NOx: 0-50-1000ppm, humidity: 0-40%
Dust: 0 ~ 10mg / m3, 0 ~ 50mg / m3
Flow rate: 0 ~ 40m / S (customizable)
Temperature: 0 ~ 300 ℃ (customizable)
Pressure: - 10KPA ~ + 10KPA (customizable)
Size: 580mm × 290mm × 1060mm
Heat tracing temperature: 120 ℃
Protection grade: cabinet ip42, others IP65
Power supply: 220VAC, 2000W
Working temperature: - 10 ℃~ + 50 ℃
Working humidity: 0-95% RH (no condensation)
Compressed air requirements: (0.4-0.8) MPa, 0.25m3/min,
Clean without oil and water
Not yet