Welcome to the website of green ring technology (Tianjin) Co., Ltd!

  • 022-29398436

On line automatic monitor for total Escherichia coli

Agriculture, forestry, animal husbandry and fishery, industrial and mining enterprises, municipal engineering,hydrology

and water conservancy, scientific research institutions, real estate and construction industry, etc

On line automatic monitor for total Escherichia coli
Wtf5600 colitech type on-line analyzer is used to monitor the value of E.coli in medical wastewater and drinking water. The instrument is based on national standard or industry standard, which has the characteristics of simple operation, high automation, easy maintenance and low cost of consumables. The instrument is equipped with rs485/rs232 interface as standard, which supports Modbus protocol. It can master its operation status and data through remote communication, and also can control it remotely, realize remote analysis, remote calibration Remote cleaning and other advanced functions. The accuracy of the analysis and other indicators are better than the relevant national standards. This product is suitable for: hospital sewage, drinking water source, surface water quality automatic monitoring station, sewage treatment plant outlet, etc.
Product overview

Wtf5600 colitech type on-line analyzer is used to monitor the value of E.coli in medical wastewater and drinking water. The instrument is based on national standard or industry standard, which has the characteristics of simple operation, high automation, easy maintenance and low cost of consumables. The instrument is equipped with rs485/rs232 interface as standard, which supports Modbus protocol. It can master its operation status and data through remote communication, and also can control it remotely, realize remote analysis, remote calibration Remote cleaning and other advanced functions. The accuracy of the analysis and other indicators are better than the relevant national standards.

This product is suitable for: hospital sewage, drinking water source, surface water quality automatic monitoring station, sewage treatment plant outlet, etc.

Product features

Wtf5600 colitech ensures that the detection is selective and highly sensitive. The automatic sampling frequency can be adjusted in the range of 6 times per hour and once every 24 hours. COLILERT reagent (enzyme substrate method) is a good medium for the cultivation of Escherichia coli. Advanced microelectronic technology ensures the reliability of the results. Based on the classical analysis algorithm, the patent polynosis standardized algorithm is used for data derivation.

The pipeline and operation are simplified. When installing, just connect the reagent, sample, waste liquid pipeline and power line, and set the parameters to start. The data can be stored for a long time and can be exported by USB. Low maintenance, automatic operation, short preparation time, no special electrician training; Low liquid consumption, low operation and maintenance cost, reduce secondary pollution.

performance parameter

Performance parameters of wtf5600 colitech

Analysis method

Enzyme substrate method

Analysis range

0-100mpn / 100mL, 0-10000mpn / 100ml (expandable)

detection limit

1MPN/mL

resolving power

1%

Error

The standard solution is less than 10%;Water sample < 10%

Repeatability

5%

Span Drift

±5% F.S.

Analysis method

On the hour

Run hourly, up to 2 groups per day

 

Interval

Run for 0-9999 minutes at the set interval

 

Manual

Manual analysis

 

long-range

Modbus is used for remote control;Dry contact control

Calibration mode

Interval times

Interval calibration according to the number of analysis accumulation

 

Interval days

Interval calibration by operation days

 

Manual

Manual calibration

 

long-range

Remote control by MODBUS

Cleaning method

Automatic

Analysis and cleaning;Fault cleaning;Abnormal power off cleaning;Emergency stop cleaning

 

Manual

Manual cleaning

call the police

Lack of liquid alarm;Self check alarm;Fault alarm;Over limit alarm (one way relay)

Data

One 4-20mA analog

Communications

A standard Modbus protocol of RS232 or RS485 interface

Storage

About 20000 sets (automatically saved after power failure);Support u disk to export Excel;

Printing

Miniature industrial thermal printer (optional)

Maintenance cycle

About 30 days, 45 minutes

Display unit

7Inch LCD, 800 * 480 resolution, TFT true color touch screen

Use environment

5-35 ℃, humidity < 90% (no condensation)

Water sample temperature

5—35℃

Water extraction unit

For the circulation and retention of water samples;Automatic back flushing precision filtration system (optional)

Dimensions

one thousand six hundred and fifty×five hundred and thirty×430mm (including reagent cabinet)

Weight

45kg (including reagent cabinet)

Power Supply

AC 220V ± 10%, 50Hz ± 1%

Power

150W

technical service

Green ring company provides you with:

1. Water quality monitoring technical consultation and formulation of application scheme

2. Customized supporting products according to the site environment

3. Debugging and acceptance of instruments and supporting equipment

4. On site training of instrument use methods and precautions

5. After sales maintenance and repair service

Green ring company can provide customized product services for customers to meet their on-site needs. The supporting products provided by Jingxiang company include:

one   Data acquisition and transmission network: remote transmission of field data to the user terminal (server, PC terminal), to achieve remote monitoring, according to the communication protocol provided by the user     Develop the data format and connect with the local relevant departments.

two   Analysis data PC client: through the configured computer, the analysis data will be transmitted to the computer in real time, or connected with the outdoor LED electronic LCD screen.

three   Water quality regulation dosing unit: according to the instrument analysis data, real-time regulation of supporting dosing equipment, inlet and outlet valves and other third-party equipment.

four   Pump control unit: it provides the control service of pump equipment on site, and can realize manual / automatic operation.

five   Water quality pretreatment unit: in view of the conditions of high temperature and high pollution of water samples, it is necessary to carry out physical purification or cooling treatment for water samples, so as to meet the requirements of analysis. 

Some consumables and accessories

name

Company

Recommended replacement cycle (6 times / day)

Analytical reagent

Set (1L)

2Months

Standard sample

Set (1L)

3Months

Peristaltic pump pipe stuck

root

6Months

Drain pipe

root

6Months


Green ring promises that the reagent formula is fully open. Jingxiang provides analytical reagents and standard samples for customers to prepare.

Last product :
No Data
No Data
: Next product